Part Number Hot Search : 
GBJ2510 TEA6849 D1768 C2012 BZX85C11 NTX1N F130457 TC9307AF
Product Description
Full Text Search
 

To Download U1600 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  introduction the U1600 series handheld digital oscilloscope has a 4.5-inch lcd color display, which helps to clearly distinguish waveforms between two channels. this U1600 series provides a high performance troubleshooting and quality assurance tool for technical professionals in the installation, maintenance, service, and automotive industries. the U1600 series consists of two models: u1602a/u1602b C 20 mhz oscilloscope and u1604a/u1604b C 40 mhz oscilloscope. each model has a real-time sampling rate of up to 200 msa/s. users can use the dual waveform math (dwm) and fast fourier transform (fft) functions (in the u1604a/u1604b model) to perform quick waveform analyses in both time and frequency domains. the built-in 6000 resolution count true rms digital multimeter (dmm) comes with an auto-range feature that gives users the fexibility to perform quick and accurate meter measurements including voltage, resistance, and auxiliary measurements. in addition, the standard versions of the U1600 series models also contain a data logger function. the series latest oscilloscopes, the u1602b and u1604b come in vivid orange cases, offering capabilities and functions equivalent to the U1600a series. a scope, true rms dmm, a real- time data logger in one instrument the U1600 series is a robust, high performance and reliable handheld wave - form and meter measurement tool for to - days challenging industrial environments. not only do these instruments provide fully featured oscilloscope functions, but also a 6,000-count true rms dmm with real-time data logger. the dmm measure - ment functions include a voltmeter (for dc voltage, ac voltage and true rms ac + dc voltage measurements), an ohmmeter (for 2-wire resistance, capacitance, diode and continuity tests), and an auxiliary meter (for temperature, ampere measurement)*. * additional accessories required and offered as optional U1600 series handheld digital oscilloscopes delivering more functionality and performance with a handheld digital oscilloscope data sheet features three-in-one solution: dual ? channel oscilloscope, true rms dmm, and real-time data logger large 4.5 color lcd display ? up to 40 mhz bandwidth with ? advanced triggering up to 200 msa/s sampling rate ? up to 125 000 points recording ? length ? 22 automatic scope measurement functions available 6,000-count dmm resolution with ? built-in measurement functions including voltmeter, ohmmeter, and auxiliary meter zoom and dual waveform math ? functions (additional fft function with four windowing techniques available in u1604a/ u1604b) full remote control and data ? transfer via pc link application software usb 2.0 full-speed interface ? connectivity multi-language quick help ? support
2 clearly distinguish your waveform the U1600 series models come with a color display, which allows you to quickly and clearly identify your signal between two channels. the large lcd display C 4.5 with 320 x 240 resolution C makes it much easier for you to view more pieces of information at one glance. capture signal deviations, glitches and dropouts effectively the U1600 series offers the best product specifcation for users. this instrument provides a real-time sam - pling rate of up to 200 msa/s. use the U1600 series to capture both instanta - neous and repetitive signal anomalies effectively. high-precision zoom-in capability in deep memory with 125 kilobytes of physical memory, you can capture non-repeating signals at a higher sampling rate over a wider time base. with up to 125 000 points recording length, you can quickly zoom in the segment of interest and uncover even the most subtle details of the signal at a given time-base setting. isolate and analyze the signal you want to see the U1600 series comes with fexible triggering capabilities that allow you to isolate and capture the condition you want to characterize. the advanced triggering function includes edge, pulse width, pattern, and video signal triggering, giving you the fexibility needed to best capture your signal. figure 1 high-defnition of color resolution in large 4.5 lcd display allows you to quickly distinguish and identify your signals and observe signal activity. figure 2 with up to 125 000 points recording length, use the zoom-in function to magnify a signal to the segment of your interest and scrutinize subtle details of your signals. before zoom after zoom
3 fft (u1604a/u1604b only) and dual waveform math functions for waveform analysis besides of the standard dual waveform math (dwm) function in U1600 series, the u1604a/u1604b model is equipped with a fft (fast fourier transform) function. this function allows you to view the waveform in a frequency domain using four windowing techniques (rectangular, hanning, hamming, black-harris). use the dwm function to perform math functions for signal addition and subtraction from multiple channels. easy, straightforward connectivity the U1600 series expands the oscilloscopes capability with the pc link application software that caters for data collection, storage and documentation needs from instrument via usb 2.0 full-speed connection. this pc link application software is available for you to control the instrument remotely from a pc, retrieve your waveform and print it using a connected printer. connect a usb fash drive via the usb host port to store your waveform and confguration setup. this feature is available as an option (option 001) to users. built-in multi-lingual quick help menu provides instant assistance need assistance while operating the instrument? the built-in multi-lingual quick help menu helps to minimize downtime in the event that you need help to set up scope and dmm functions. the supported languages include english, german, italian, spanish, portuguese, french, korean, traditional chinese, simplifed chinese, and japanese. save and recall waveform and setup memories capability up to 10 waveforms and confguration setups can be stored in the instrument and recalled at any time for future use and reference. figure 3 the U1600 series comes equipped with dwm features, allowing you to perform spectrum analyses and evaluate signal additions and subtractions from multiple channels. screen capture window data measurement window dso controller waveform data window dmm data logging window figure 4 pc link application software is available to enable data collection, storage and documentation needs via usb full-speed remote control from pc. log data for any dmm measurement the sophisticated logger mode allows you to record and consolidate a sequence of data points for data plotting purposes.
4 scope specifications [1] vertical system: scope channels bandwidth (C3 db) u1602a/u1602b: dc to 20 mhz u1604a/u1604b: dc to 40 mhz dc vertical gain accuracy 5 mv/div to 20 mv/div: 5% full scale 50 mv/div to 100 v/div: 3% full scale scope channel triggering trigger sensitivity dc to 5 mhz: 0.8 divisions u1602a/u1602b: 5 mhz to 20 mhz C 1 division u1604a/u1604b: 5 mhz to 40 mhz C 1 division scope characteristics [2] acquisition: scope channels maximum sample rate 100 msa/s per channel (50 s/div to 250 ns/div) 3 200 msa/s single channel and interleaved (125 ns/div) 4 equivalent sample rate u1604a/u1604b: 2.5 gsa/s (125 ns/div to 10 ns/div) vertical resolution 8 bits maximum recording length: u1602a/u1604a: up to 11 100 points, viewable on screen with zoom function u1602b/u1604b: up to 125 000 points, viewable on screen with zoom function peak detection 5 ns average selectable in average number of 2, 4, 8, 16, 32, 64, 128, 256 vertical system: scope channels analog channels channel 1 and channel 2 simultaneous acquisition bandwidth (C3 db) u1602a/u1602b: dc to 20 mhz u1604a/u1604b: dc to 40 mhz ac coupled < 10 hz without probe < 1 hz with 10 m w 10:1 probe rise time u1602a/u1602b: < 17.5 ns u1604a/u1604b: < 8.8 ns single shot bandwidth u1602a/u1602b: 20 mhz u1604a/u1604b: 40 mhz vertical sensitivity 5 mv/div to 100 v/div (1:1 scope probe) 50 mv/div to 1 kv/div (10:1 scope probe) 500 mv/div to 10 kv/div (100:1 scope probe) maximum input cat iii 300 vrms (up to 400 hz) from terminal to ground offset/dynamic range 5 div input impedance 1 m w i i < 20 pf coupling ac, dc, gnd [1] all specifcations are warranted. specifcations are valid after a 30-minute warm-up period and within a range of 10 oc from frmware calibration temperature. [2] all characteristics are typical performance values and are not warranted. characteristics are valid after a 30-minute warm-up period and within a range of 10 oc from frmware calibration temperature. [3] maximum sampling rates are shown here. sampling rate will vary according to selected time base. for more information, please refer to users and service guide. [4] 200 ms/s sampling rate is only available at 125 ns/div timebase [5] number of points displayed will vary according to time base selected. for more information, refer to users and service guide
5 noise peak-to-peak 3% of full scale or 5 mv, whichever is greater dc vertical offset accuracy 0.1% div 2 mv 0.5% offset value single cursor accuracy 4% full scale dual cursor accuracy 4% full scale horizontal system range u1602a/u1602b: 50 ns to 50 s/div u1604a/u1604b: 10 ns to 50 s/div resolution u1602a/u1602b: 2 ns u1604a/u1604b: 400 ps reference position left, center, right delay range (pre-trigger) 15 divisions delay range (post-trigger) 1000 divisions analog d t accuracy 3% reading 0.4% screen modes main, xy, roll rms jitter 5% of horizontal scale or 5 ns, whichever is higher trigger system source channel 1 and channel 2 modes auto, normal, single selections edge pattern pulse width video edge, pulse width, pattern, video trigger on a rising or falling edge of any source trigger at the beginning of a pattern of high, low levels and rising or falling edge established conditions of and, or, nor and nand between the channels. 200 ns to 10 s. trigger when a positive or negative pulse width of any source larger than, less than, equal to or not equal to duration. video trigger sensitivity: 0.7 division trigger level. available to both channel 1 and channel 2. analog progressive and interlaced video standards including ntsc, pal and secam. positive or negative sync pulse polarity. modes C all felds, even felds, odd felds or line 5 C 263 within a feld. range 4 divisions from center screen level accuracy 0.5 divisions trigger sensitivity dc to 5 mhz: 0.8 divisions u1602a/u1602b: 5 mhz to 20 mhz C 1 division u1604a/u1604b: 5 mhz to 40 mhz C 1 division coupling dc, ac (< 1 hz), hf reject (> 50 khz), lf reject (< 30 khz), noise reject probe attenuation factors 1x, 10x, 100x coupling 3 vp-p, ~ 1 khz maximum probe input 1x cat iii 300 vac 10 x, 100x cat iii 600 vac probes u1560-60001: 1:1 passive probe u1561-60001: 10:1 passive probe u1562-60001: 100:1 passive probe
6 digital multimeter specifcations [1] (% reading + % range) funtion range frequency, test current or burden voltage 1 year tcal 5o c dc voltage 600.0 mv 6.000 v 60.00 v 600.0 v 0.3 + 0.08 0.3 + 0.08 0.3 + 0.08 0.3 + 0.08 ac voltage 600.0 mv C 600.0 v 50 hz C 1 khz 1 khz C 30 khz 1.0 + 0.2 3.0 + 0.2 ac + dc voltage 6.000 v C 600.0 v 50 hz C 1 khz 1 khz C 30 khz 1.0 + 0.2 3.0 + 0.2 resistance 600.0 w 6.000 k w 60.00 k w 600.0 k w 6.000 m w 60.00 m w 0.5 + 0.2 0.5 + 0.2 0.5 + 0.2 0.5 + 0.2 0.5 + 0.2 1.0 + 0.2 capacitance 60.00 nf 600.0 nf 6.000 f 60.00 f 300.0 f 2.0 + 0.2 2.0 + 0.2 2.0 + 0.2 2.0 + 0.2 2.0 + 0.2 diode 1.000 v 0.5 ma 2.0 + 0.08 [1] for temperatures between 0 oc to 18 oc and 28 oc to 50 oc, add 0.1% of reading + 0.02% of range for every degree celsius. cursors manually place readout of horizontal (x, d x) and vertical (y, d y). waveform math ch1 + ch2, ch1 C ch2, ch2 C ch1 fft [1] window rectangular, hanning, hamming, blackman-harris amplitude display selectable in amplitude displays of 1 db, 2 db, 5 db, 10 db measurement system autoscale finds and displays all active scope channels, sets edge trigger mode on highest numbered channel, sets vertical sensitivity on scope channel. requires voltage > 20 mvp-p, 0.5% duty cycle and frequency > 100 hz. automatic measurement measurements continuously updated. voltage peak-to-peak, maximum, minimum, amplitude, top, base, +overshoot, Covershoot, preshoot, rms, mean and one cycle mean. time frequency, period, +width, Cwidth, and +duty cycle and Cduty cycle on any channel. rise time, fall time, delay and phase shift.
7 measurement characteristics full scale reading 6,000-count dc voltage, true rms ac voltage maximum input voltage, 600 vrms cat ii, 300 vrms cat iii dc coupled input coupling continuity beeper < 60 w in 600 w range data logger source digital multimeter measurements range 10 divisions record size up to 2000 data points (with option 001) time span auto range 150 seconds to 20 days time reference time from start record method selectable minimum, maximum and average display system display 4.5-inch diagonal color cstn lcd resolution 320 x 240 pixels control contrast control, infnite persistance on/off built-in help system functional help displayed by pressing help button real-time clock time and date (user-adjustable) storage save/recall (non-volatile) up to 10 setups and traces auxiliary meter specifcations (% of reading + % of range) function range frequency 1 year tcal 5 oc temperature [2] , oc 600.0 oc 0.3 + 0.08 6000 oc 0.3 + 0.08 temperature [2] , of 600.0 of 0.3 + 0.08 6000 of 0.3 + 0.08 ac current [3] 60.00 a 50 hz C 1 khz 1.0 + 0.2 600.0 a 50 hz C 1 khz 1.0 + 0.2 [2] u1586b temperature module is needed to make measurements and is available as option. [3] u1583b ac current clamp needed to make measurements and is available as option.
8 item u1602a/ u1604a u1602b/ u1604b u1560a 1:1 scope probe x - u1561a 10:1 scope probe x x (2 units) u1580a test leads x x u1162a alligator clips x x usb cable x x u1570a ac power adapter and cord x x u1571a ni-mh battery pack x x quick start guide x x certifcate of calibration x x general characteristics power adapter line voltage range 50/60 hz, 100 C 240 vac output voltage 12 vdc battery ni-mh rechargeable battery pack 7.2 v, 4500 mah operating time: 4 hours charging time: 5 hours, measurement unit off allow ambient temperature during charging: 10 oc to 40 oc operating environment temperature operating full accuracy 0 oc to 50 oc non-operating C20 oc to 70 oc humidity operating full accuracy to 80% rh at 40 oc altitude operating full accuracy up to 2000 m non-operating 15000 m (50000 ft) esd tolerance 4 kv safety compliance iec 61010-1: 2001/en61010-1: 2001 csa c22.2 no. 61010-1: 2004 pollution degree 2 this instrument is rated for indoor use only. dimensions (h x w x d) 24.1 cm height x 13.8 cm width x 6.6 cm depth weight 1.5 kg i/o usb 2.0 full-speed client (standard) usb 2.0 full-speed host (option 001) firmware upgrade through usb. warranty 3 years for main unit 3 months for standard shipped accessories unless otherwise stated. s tandard shipped items ordering i nformation: u1602a u1604a u1602b u1604b
9 optional accessories item description u1168a standard test lead kit (with 19-mm and 4-mm probe tips) ? test leads: cat iii 1000 v, cat iv 600 v, 15 a ? test probe (19-mm tips): cat iii 1000 v, cat iv 600 v, 15 a ? test probe (4-mm tips): cat iii 1000 v, cat iv 600 v, 15 a (highly recommended for cat iv environment) ? alligator clips: cat iii 1000 v, 10 a ? fine tip test probes: cat ii 300 v, 3 a ? smt grabber: cat ii 300 v, 3 a ? mini grabber (black only): cat ii 300v, 3 a u1161a extended test lead kit ? includes two test leads (red and black), two test probes, medium sized alligator clips and 4 mm banana plugs ? test leads: cat iii 1000 v, cat iv 600 v, 15 a ? test probes: cat iii 1000 v, 15 a ? medium sized alligator clips: cat iii 600 v, 10 a ? 4 mm banana plugs: cat ii 600 v, 10 a u1162a alligator clips ? one pair of insulated alligator clips (red and black) ? recommended for use with agilent standard test leads ? rated cat iii 1000 v, 10 a u1163a smt grabbers ? one pair of smt grabbers (red and black) ? recommended for use with agilent standard test leads ? rated cat ii 300 v, 3 a u1164a fine-tip test probes ? one pair of insulated alligator clips (red and black) ? recommended for use with agilent standard test leads ? rated cat ii 300 v, 3 a u1169a test probe leads (with 19-mm tips and 4-mm tips) ? test leads: cat iii 1000 v, cat iv 600 v, 15 a ? test probe (19-mm tips): cat iii 1000 v, cat iv 600 v, 15 a ? test probe (4-mm tips): cat iii 1000 v, cat iv 600 v, 15 a (highly recommended for cat iv environment) u1181a immersion temperature probe ? type-k thermocouple for use in oil and other liquids temperature measurements ? measurement range: C50 c to 700 c ? temperature module (u1586a) is required to connect to dmm inputs of the handheld scope ? u1184a temperature probe adapter included for use with dmms u1182a industrial surface temperature probe ? type-k thermocouple for use in still surface temperature measurements ? measurement range: C50 c to 400 c ? temperature module (u1586a) is required to connect to dmm inputs of the handheld scope ? u1184a temperature probe adapter included for use with dmms u1183a air temperature probe ? type-k thermocouple for use in air and non-caustic gas temperature measurements ? measurement range: C50 c to 800 c ? temperature module (u1586a) is required to connect to dmm inputs of the handheld scope ? u1184a temperature probe adapter included for use with dmms
10 item description u1560a 1:1 scope probe ? includes ground alligator and hook clips ? rated cat iii 300 v ? frequency range from 0 to 45 mhz u1561a 10:1 scope probe ? includes ground alligator and hook clips ? rated cat iii 600 v ? frequency range from 0 to 250 mhz u1562a 100:1 scope probe ? includes ground alligator and hook clips ? rated cat iii 600 v ? frequency range from 0 to 300 mhz u1570a ac power adapter ? ac power adapter for handheld scope ? includes ac power based on country u1554a hook clip for probe tip ? rated cat ii 1000 v, cat iii 600 v u1571a ni-mh battery pack ? 4500 ma, 7.2 v u1580a dmm terminal test lead set ? includes dmm test probe leads and dmm alligator clips ? rated cat iii 1000 v u1583b ac current clamp ? dual range (40 a and 400 a) ? rated cat iii 600 v ? bnc-to-banana plug provided, for use with dmms or handheld scope u1586b temperature module ? measure C50c to 1000c/C58f to 1832f ? k-type bead probe supplied ? can be used with u1181a, u1182a, and u1183a u1590a soft carrying case ? dimensions: 9.6? (h) x 13.0? (w) x 4.5? (t) ? pvc leather material
agilent email updates www.agilent.com/fnd/emailupdates get the latest information on the products and applications you select. www.lxistandard.org lxi is the lan-based successor to gpib, providing faster, more efficient connectivity. agilent is a founding member of the lxi consortium. agilent channel partners www.agilent.com/find/channelpartners get the best of both worlds: agilents measurement expertise and product breadth, combined with channel partner convenience. americas canada (877) 894 4414 latin america 305 269 7500 united states (800) 829 4444 asia pacific australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 112 929 japan 0120 (421) 345 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 thailand 1 800 226 008 europe & middle east austria 43 (0) 1 360 277 1571 belgium 32 (0) 2 404 93 40 denmark 45 70 13 15 15 finland 358 (0) 10 855 2100 france 0825 010 700* *0.125 /minute germany 49 (0) 7031 464 6333 ireland 1890 924 204 israel 972-3-9288-504/544 italy 39 02 92 60 8484 netherlands 31 (0) 20 547 2111 spain 34 (91) 631 3300 sweden 0200-88 22 55 switzerland 0800 80 53 53 united kingdom 44 (0) 118 9276201 other european countries: www.agilent.com/find/contactus revised: october 1, 2009 www.agilent.com www.agilent.com/find/handheldscope for more information on agilent technologies products, applications or services, please contact your local agilent office. the complete list is available at: www.agilent.com/find/contactus ? agilent technologies, inc. 2009 printed in usa, december 1, 2009 5989-5576en product specifications and descriptions in this document subject to change without notice. remove all doubt our repair and calibration services will get your equipment back to you, performing like new, when promised. you will get full value out of your agilent equipment through- out its lifetime. your equipment will be serviced by agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. you will always have the utmost confidence in your measurements. for informa - tion regarding self maintenance of this product, please contact your agilent office. agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. for more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt


▲Up To Search▲   

 
Price & Availability of U1600

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X